Frequency domain electromagnetic induction sounding is the full title of the method, hardwared in EMS devices. Hereby presented paper includes material made by two

devices: EMS-2 and EMS-3. EMS3 improvements are the matter of design, power consumption, weight and speed of data acquisition.

The device novelty is the realisation of 3-coils device for swface investigation. Instead of two coils - transmitting and receiving - as in the usual Slingram devices, EMS-3 has one transmitting and two receiving coils that allow to compensate primary field and drastically improves the device features.

EMS was tested at numerous sites in Russia, Italy and Antarctica. Comparison with GEM-300, EM-31, EM-34, georadar and DC resistivity tomography were done; In al1 the cases a good correlation between various instrumentation was obtained; Meanwhile, EMS featured better noise resitance, sensitivity and resolution in addition to the unique feature: ability to visualize data as cross-section and pseudo3D view as wel1 as a map right in the field.

Итоговая версия опубликована: Сборник трудов 9Ih Meeting of Environmental and Engineering Geophysics, Prague, August 31 - September 4,2003 Czech Republic

НПО "Терразонд"Спонсор «ГеоИнфо»

Опубликовано с разрешения автора.

Поделиться
Рубрикатор материалов

Сейчас в информационной базе:
рубрик - 71 , авторов - 318 ,
всего информационных продуктов - 2905 , из них
статей журнала - 604 , статей базы знаний - 85 , новостей - 2074 , конференций - 4 ,
блогов - 8 , постов и видео - 106 , технических решений - 4

Copyright © 2016-2019 ГеоИнфо
Все права защищены

Разработка и сопровождение: InfoDesigner.ru

Отправить сообщение, заявку, вопрос

Отправить заявку на посещение мероприятия

Отправить заявку на участие как экспонент

Запросить консультацию специалистов по данному техническому решению